Model
|
AC-SW12H08
|
|
Technology
|
Standard
|
IEEE802.3 10 Base-T, IEEE802.3u 100 Base-TX/FX
IEEE802.3, IEEE802.3af
|
|
Forward and Filtering Rate
|
14,880pps for 10Mbps
|
|
148,810pps for 100Mbps
|
|
Packet Buffer Memory
|
1M bits
|
|
Processing Type
|
Store-and -Forward
|
|
Half-duplex Back-pressure and
IEEE802.3x Full-duplex Flow Control
|
|
Address Table Size
|
1024 MAC Address
|
|
Power
|
Input Voltage
|
48VDC (Terminal Block; DC Jack) for 15.4W per PoE Port
55VDC (Terminal Block; DC Jack) for 30W per PoE Port
|
|
Power Consumption
|
72W Max. 1.5A@48VDC
130W Max. 2.3A@55VDC
|
|
Overload Current Protection
|
Present
|
|
Reverse Polarity Protection
|
Present
|
|
Mechanical
|
Casing
|
Aluminum Case
|
|
IP30
|
|
Dimensions
|
68mm (W) x 110mm (D) x 135mm (H)
(2.68" (W) x 4.33" (D) x 5.31" (H))
|
|
Weight
|
1Kg (2.2lbs)
|
|
Installation
|
DIN-Rail (Top Hat Type 35mm), Panel, Rack Mounting
|
|
Interface
|
Ethernet Port
|
10/100Base-TX: 8, 7 or 6 Ports
|
|
100Base-FX: 0.1 or 2 Ports
|
|
LED Indicators
|
Per Unit: Power Status (Power 1, Power 2, Power 3)
|
|
Per Port: 10/100TX, 100FX: Link/Activity (Green)
PoE: Link (Amber)
|
|
Alarm Contact
|
One Relay Output with Current 0.1A@24VDC
|
|
Environment
|
Operating Temperature
|
﹣40°C to 75°C (-40°F to 167°F)
Tested @ ﹣40°C to 85°C (-40°F to 185°F)
|
|
Storage Temperature
|
﹣40°C to 85°C (-40°F to 185°F)
|
|
Ambient Relative Humidity
|
5% to 95% (Non-Condensing)
|
|
Regulatory Approvals
|
ISO
|
Manufactured in an ISO9001 Facility
|
|
Safty
|
UL508, EN60950-1, IEC60950-1
|
|
EMI
|
FCC Part 15, Class A
|
|
EN61000-3-2 → EV55022 / EN61000-3-2 / EN61000-3-3
|
|
EMS
|
EN61000-6-2
→ EN61000-4-2 (ESD Standards)
Contact: +/- 4KV; Criteria B
Air: +/- 8KV; Criteria B
→ EN61000-4-3 (Radiated RFI Standards)
10V/m, 80 to 1000MHz; 80% AM Criteria A
→ EN61000-4-4 (Burst Standards)
Signal Ports: +/- 4KV; Criteria B
→ EN61000-4-5 (Surge Standards)
Signal Ports: +/- 1KV;Line-toLine; Criteria B
D.C. Power Ports: +/- 0.5KV; Line-to-Earth; Criteria B
→ EN61000-4-6 (Induced RFI Standards)
Signal Ports: 10Vrms @ 0.15 ~ 80MHz; 80% AM Criteria A
D.C. Power Ports: 10Vrms @ 0.15 ~ 80MHz; 80% AM Criteria A
→ EN61000-4-8 (Magnetic Field Standards)
30A/m @50, 60Hz; Criteria A
|
|
Environmental Test Compliance
|
IEC60068-2-6 Fc (Vibration Resistance)
5g @10 ~150KHz, Amplitude 0.35mm (Operation/Storage/Transport)
|
|
IEC60068-2-27 Ea (Shock)
25g @ 11ms (Half-Sine Shock Pulse; Operation)
50g @ 11ms (Half-Sine Shock Pulse; Storage/Transport)
|
|
IEC60068-2-32 Ed (Free Fall)
1M (3.281ft.)
|
|
NEMA TS1/2 Environmental Requirements for Traffic Control Equipment
|